A structured evaluation of energy consumption, equipment performance and energy-saving opportunities based on the ISO 50002 energy audit framework.
We help industrial and commercial organisations turn facility data and site observations into practical, prioritised opportunities for better energy performance.
Understand. Evaluate. Improve.
A Clearer View of Your Energy Performance
Our assessment helps you understand where and how energy is consumed, identify significant energy users, evaluate equipment and system performance, detect avoidable losses, and develop practical energy conservation measures.
Understand energy consumptionIdentify significant energy usersAssess system performanceDetect avoidable energy lossesDevelop practical conservation measuresPrioritise technical and financial opportunitiesEstablish a performance-improvement foundationSupport informed investment decisions
From Scope to Action
Our ISO 50002-Based Energy Audit Framework
The audit level, measurements and depth of analysis are agreed around your objectives, available information and facility conditions.
1
Preliminary Consultation and Audit Planning
Understand the facility, operations and client objectives
Define scope, boundaries and level of detail
Identify required documents, data and responsible personnel
Establish the schedule and measurement plan
2
Energy Data and Document Review
Review electricity bills, fuel records and consumption trends
Review production or operating data
Examine equipment lists, schedules and process information
Identify initial patterns and investigation priorities
3
Site Assessment and Walk-Through
Inspect major energy-consuming systems
Observe operating practices and equipment conditions
Discuss operational issues with relevant personnel
Identify visible losses, control issues and opportunities
4
Measurement and Data Collection
Depending on scope, measurements may cover electrical power and energy, current, voltage, power factor, load profile, flow, temperature, pressure, air velocity, equipment loading, operating hours and process parameters.
Methods, instruments and monitoring duration depend on the equipment, operating conditions and audit requirements.
5
Energy Performance Analysis
Develop an energy balance where applicable
Identify significant energy users and evaluate efficiency
Compare performance with design data, suitable references or accepted engineering practice
Analyse relevant operating variables, losses and inefficient conditions
6
Energy-Saving Opportunity Identification
Operational, control and maintenance optimisation
Equipment upgrades and waste-heat recovery
Reduced electrical, thermal or compressed-air losses
Better sizing, scheduling, loading, monitoring and management
7
Technical and Financial Evaluation
Estimated energy and cost savings
Implementation cost and simple payback, where data permits
Operational impact and technical feasibility
Priority, key assumptions and limitations
8
Audit Report and Management Presentation
Executive summary, facility profile and audit scope
Consumption profile, significant users and measurements
System performance, opportunities and financial indicators
Priorities, assumptions, limitations and follow-up actions
Findings may be presented to management or the client’s technical team.
Systems and Equipment We Assess
Coverage is tailored to the agreed audit scope; an audit does not automatically include every system listed below.
⚡
Electrical Distribution
M
Motors and Driven Equipment
P
Pumps and Pumping Systems
F
Fans and Ventilation
❄
Chillers and Air-Conditioning
A
Air-Compressors
B
Boilers and Thermal Systems
S
Steam and Hot Water
L
Lighting Systems
°C
Process Heating and Cooling
U
Building and Facility Utilities
+
Other Significant Energy Users
Verify Actual Performance
Audit Measurement Support
Site measurements may be conducted where required to verify actual equipment and system performance. Measurement points, monitoring duration and instrument selection will be determined based on the system being assessed, site accessibility and the agreed audit scope.
Possible instruments
Power analyser
Clamp meter
Ultrasonic clamp-on flowmeter
Hot-wire anemometer
Infrared temperature gun
Other suitable instruments for the audit requirement
Documented for Decision-Making
Typical Deliverables
Energy-consumption review and energy-use breakdown
Significant energy-user identification
Site assessment findings
Measurement and performance analysis
Energy-saving opportunity register
Preliminary technical recommendations
Estimated energy and cost savings
Simple payback analysis where applicable
Prioritised implementation action plan
Management presentation or close-out discussion
Key assumptions, limitations and follow-up actions
Final deliverables depend on the agreed scope, data availability and level of audit.
Who This Service Is For
Manufacturing facilitiesCommercial buildingsHotelsHospitals and healthcare facilitiesWarehouses and logistics facilitiesData- or utility-intensive operationsOrganisations reducing energy costOrganisations preparing for an EnMSFacilities clarifying major users and savings
Benefits to Your Organisation
Better energy visibilityIdentification of avoidable lossesImproved system performanceBetter project prioritisationReduced energy and operating costsImproved maintenance practicesStronger capital-expenditure justificationSupport for continual improvementBetter preparation for an EnMS
Start Understanding Where Your Energy Is Going
Discuss your facility, major energy-consuming systems and current energy challenges with us. We can help define a suitable energy audit scope based on your objectives and available data.